  • Fast multi-point Auto Calibration — Simple calibration workflow with on-screen guidance and self diagnosis, automatically recognizing pH calibration buffers 1.68, 4.00, 7.00, 10.01, 12.45 and conductivity calibration solutions 1413 µS/cm, 12.88 mS/cm, 84 µS/cm, 1118.mS/cm.
  • Electrode Health Monitoring — Real-time slope display between pH calibrations helps you quickly assess the condition and performance of your pH electrode.
  • GLP-Ready Data Management — Stores up to 1000 data sets with timestamps. USB data output supports smooth transfer to PC-link for audits, reporting, and further analysis.
  • Cross-Platform Web-based PC-Link Software (Open with Chrome/Edge/Firefox) — No installation required—just plug in and retrieve all stored measurements at once, offering real-time charts and one-click export to CSV or professional PDF reports (including measurements, calibration date, pH electrode slope, offset, meter model and serial number).
  • 201T-F All-in-One pH/Temp Electrode — Built with Apera’s proprietary lithium-glass membrane for high stability and accuracy. The dual ceramic–fiber junction minimizes clogging, while the integrated temperature sensor enables true automatic temperature compensation (ATC). Detachable sensor shield protects the sensitive glass bulb.
  • 2301T-F ATC Conductivity Electrode — Featured with a proprietary firm platinum-black cell (K=1.0) for exceptional stability and ±1% F.S. accuracy across a wide range (0 to 200 mS/cm)
  • Universal BNC Electrode Compatibility — Standard BNC connector works seamlessly with Apera’s LabSen® pH electrodes, supporting a wide range of specialty pH applications.

Browse our catalogue

SKU: PC800 Category: Tags: , , Brand:

Parameter Settings Menu

Mode Symbol Parameter Options Factory Default
P1.0 — pH P1.1 Select Buffer Series USA / NIST —
P1.2 Set Calibration Reminder No / H00–H99 / D00–D99 No
P1.3 Check Calibration Date & Time — —
P1.4 Restore Factory Default No / Yes No
P2.0 — Conductivity P2.1 Select Electrode Constant 1.0 / 10.0 / 0.01 1.0
P2.2 Set Calibration Reminder No / H00–H99 / D00–D99 No
P2.3 Check Calibration Date & Time — —
P2.4 Select Reference Temperature 15–30 °C 25 °C
P2.5 Adjust Temp. Compensation Coefficient 0.00–9.99% 2.00%
P2.6 Adjust TDS Factor 0.40–1.00 0.71
P2.7 Restore Factory Default No / Yes No
P5.0 — Basic Parameter P5.1 Adjust Timing for Auto Storage 0–99 hr, 0–59 min —
P5.2 Select Temperature Unit °C / °F —
P5.3 Clear Data Storage No / Yes —
P5.4 Set Auto-Lock Reading Mode Off / On —
P5.5 Adjust Date MM / DD / YYYY —
P5.6 Adjust Time HH / MM —

 

Parameter Model PC800
pH Electrode 201T-F 3-in-1 Combination pH Electrode
Measuring Range (-2 to 19.99) pH
Resolution 0.1/0.01 pH
Accuracy ±0.01 pH ±1 digit
Input Current ≤1×10-12A
Input Impedance ≥1×1012 Ω
Stability ±0.01 pH/3h ±1 digit
Temp. Compensation Range 0 to 100°C (32 to 212°F) auto or manual
mV Measuring Range ±1999 mV
Resolution 1 mV
Accuracy ±0.1% F.S ±1 digit
Conductivity Electrode 2301T-F Combination Conductivity Electrode
Measuring Range Conductivity:
0 to 200.0 mS/cm, include:
(0.00~19.99) μS/cm
(20.0~199.9) μS/cm
(200~1999) μS/cm
(2.00~19.99) mS/cm
(20.0~199.9) mS/cm
TDS: (0 to 100) g/L
Salinity: (0 to 100) ppt
Resistivity: (0 to 100) MΩ?cm
Resolution 0.01/0.1/1μS/cm
0.01/0.1 mS/cm
Accuracy ±1.0% F.S.
Temp. Compensation Range 0 to 50°C (32 to 122°F) auto or manual
Electrode Constant 0.01/0.1/1/10 cm-1
Temp. Measuring Range 0 to 100°C (32 to 212°F)
Resolution 0.1°C
Accuracy ±0.5°C ±1 digit
Others Data Storage 1000 sets
Storage Content Numberings, Date, Time,
Measurements, Unit, Temperature, Calibration Data
Data Output USB
Power Supply Input: 120V AC 60Hz;

Output: DC9V/300mA, 2.7VA

IP Rating IP54 Splash-proof and dust-proof
Dimensions and Weight (9*9.5*6) inches /  pounds;

with case: 10*10*7 / 7 pounds approx